SAE AS 22759-13:2000 pdf download WIRE, ELECTRIC, FLUOROPOLYMER-INSULATED, FEP-PVF 2 , MEDIUM WEIGHT, TIN-COATED COPPER CONDUCTOR, 600-VOLT
TEMPERATURE RATING: 1 35°C (275°F) max conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
SPARK TEST OF PRIMARY INSULATION: 1 500 volts (rms), 60Hz, 1 00% test
IMPULSE DIELECTRIC TEST: 8.0 kilovolts (peak), 1 00% test
INSULATION RESISTANCE: 5000 megohms for 1 000 ft (min)
WRAP TEST:
“Wrap back” test required; no cracking. (See Table II, Note 3)
Oven temperature, 1 60 ±2°C (320 ±3.6°F)
BLOCKING: 1 35 ±2°C (275 ±3.6°F)
SHRINKAGE: 0.1 25 inch max at 1 50 ±2°C (302 ±3,6°F)
WICKING: No requirement
LOW TEMPERATURE (COLD BEND):
Bend temperature: -55 ±2°C (-67 ±3.6°F)
Dielectric test, 2500 volts (rms), 60Hz
THERMAL SHOCK:
Oven temperature, 1 35 ±2°C (275 ±3.6°F)
Max change in measurement
Sizes 24 through 1 2: 0.060 inch
Sizes 1 0 through 8: 0.1 00 inch
Sizes 6 through 0: 0.1 25
FLAMMABILITY: Post-flame dielectric test not required
LIFE CYCLE:
Oven temperature, 1 60 ±2°C (320 ±3.6°F)
Dielectric test, 2500 volts (rms), 60Hz
DIELECTRIC TEST AFTER IMMERSION: 2500 volts (rms), 60Hz
ABRASION RESISTANCE AFTER IMMERSION: Qualification test only
HUMIDITY RESISTANCE: 5000 megohms for 1 000 ft, min insulation resistance after humidity exposure
SURFACE RESISTANCE:
Sizes 24 through 1 2: 500 megohm-inches (min), initial and final readings
Sizes 1 0 through 0: No requirement
SMOKE: 1 50°C (302°F)
ACID RESISTANCE: No requirement
COLOR: In accordance with MIL-STD-1 04, Class 1 ; white preferred
COLOR STRIPING OR BANDING DURABILITY: 1 25 cycles (250 strokes) (min), 500 grams weight
IDENTIFICATION DURABILITY: 1 25 cycles (250 strokes) (min), 500 grams weight
WIRE LENGTH REQUIREMENTS: Schedule A
INTENDED USE: The wire of this specification sheet is intended for interconnecting and hookup applications.