IEC 60317-25:2020 pdf free download

admin
IEC 60317-25:2020 pdf free download

IEC 60317-25:2020 pdf free download Specifications for particular types of winding wires – Part 25: Polyester or polyesterimide overcoated with polyamide-imide enamelled round aluminium wire, class 200 (IEC 60317-25:2020)
1Scope
This part of lEC 60317 specifies the requirements of enamelled round aluminium windingwires of class 200 with a dual coating. The underlying coating is based on polyester orpolyesterimide resin,which can be modified provided it retains the chemical identity of theoriginal resin and meets all specified wire requirements.The superimposed coating is basedon polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change,or contains one or more additives toenhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is:- Grade 1: 0,250 mm up to and including 3,150 mm;
-Grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of lEC 60317-0-3:2008 andlEC 60317-0-3:2008/AMD1:2013.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies.For undated references, the latest edition of the referenced document (includingany amendments) applies.
IEC 60317-0-3:2008,Specifications for particular types of winding wires – Part 0-3:Generalrequirements – Enamelled round aluminium wire
lEC 60317-0-3: 2008/AMD1:2013
IEC 60317-O-3: 2008/AMD2:2019
3Terms, definitions, general notes and appearance
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 60317-0-3 apply.
ISO and lEC maintain terminological databases for use in standardization at the followingaddresses:
. IEC Electropedia: available at http://www.electropedia.orgl
. Iso Online browsing platform: available at http:/ /www.iso.orglobp
3.2 General notes
3.2.1 Methods of test Subclause 3.2.1 of IEC 6031 7-0-3:2008, IEC 6031 7-0-3:2008/AMD1 :201 3 and IEC 6031 7-0- 3:2008/AMD2:201 9 applies. In case of inconsistencies between IEC 6031 7-0-3 and this document, IEC 6031 7-25 shall prevail.
3.2.2 Winding wire Class 200 is a thermal
class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved.