IEC 60317-1:2010 pdf free download

admin
IEC 60317-1:2010 pdf free download

IEC 60317-1:2010 pdf free download Specifications for particular types of winding wires – Part 1: Polyvinyl acetal enamelled round copper wire, class 105
1 scope
This Part of lEC 60317 specifies the general requirements of enamelled round copper windingwires of class 105 with a sole coating based on polyvinyl acetal resin,which may be modifiedproviding it retains the chemical identity of the original resin and meets all specified wirerequirements.
NOTE A modified resin is a resin that has undergone a chemical change,or contains one or more additives toenhance certain performance or application characteristics.
Class 105 is a thermal class that requires a minimum temperature index of 105 and a heatshock temperature of at least 155°C.
The temperature in degrees Celsius corresponding to the temperature index is not necessarilythat at which it is recommended that the wire be operated and this will depend on manyfactors, including the type of equipment involved.
The range of nominal conductor diameters covered by this standard is as follows:- Grade 1: 0,040 mm up to and including 2,500 mm;
-Grade 2: 0,040 mm up to and including 5,000 mm;- Grade 3: 0,080 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of lEC 60317-O-1.
2Normative references
The following referenced documents are indispensable for the application of this document.For dated references,only the edition cited applies. For undated references, the latest editionof the referenced document (including any amendments) applies.
IEC 60317-0-1:2008,Specifications for particular types of winding wires – Part 0-1:Generalrequirements – Enamelled round copper wire
3Terms, definitions and general notes on methods of test and appearance3.1Terms and definitions
For terms and definitions,see 3.1 of IEC 60317-0-1. In case of inconsistencies betweenIEC 60317-0-1 and this standard,IEC 60317-1 shall prevail.
3.2General notes on methods of test
For general notes on methods of test, see 3.2 of lEC 60317-0-1. In case of inconsistenciesbetween lEC 60317-0-1 and this standard,IEC 60317-1 shall prevail.
3.3 Appearance
See 3.3 of IEC 6031 7-0-1 .
4 Dimensions
See Clause 4 of IEC 6031 7-0-1 .
5 Electrical resistance
See Clause 5 of IEC 6031 7-0-1 .
6 Elongation
See Clause 6 of IEC 6031 7-0-1 .
7 Springiness
See Clause 7 of IEC 6031 7-0-1 .
8 Flexibility and adherence
See Clause 8 of IEC 6031 7-0-1 , where the constant K used for the calculation of the number of revolutions for the peel test shall be 1 75 mm.
9 Heat shock
The minimum heat shock temperature shall be 1 55 °C.
9.1 Nominal conductor diameters up to and including 1 ,600 mm
The coating shall show no crack. The mandrel diameter shall be as specified in Table 1 .
10 Cut-through
No failure shall occur within 2 min at 1 70 °C.
11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 2,500 mm)
The wire shall meet the requirements given in Table 2.